Emergency lighting
Key words:
JC-C2021-BG of emergency lighting control system
Host 1, host and fire alarm controller adopt dry contact signal connection 2, one host controls EPS number not more than 40; 3. The number of lamps controlled by one host shall not exceed 3200 points. 4. The host and EPS shall communicate with each other through 1.5 square twisted pair, with positive and negative lines. 5. The communication distance between the host and EPS shall not exceed 1500 meters; 6. The host has built-in battery and the emergency time is more than 3 hours.
Key words:
EPS centralized power supply (lithium iron phosphate) JC-D-150W-36
EPS 1, EPS power supply is AC220V, output is DC36V;2, communication adopts power carrier, two-wire output; 3. The current of any loop shall not exceed 6A; 4. No more than 50 lamps in any loop; 5. The total length of the power line of the loop is less than 200 m; 6. EPS is equipped with 36V battery to supply emergency power to lamps.
Key words:
EPS centralized power supply (lead-acid battery) JC-D-200W-36
EPS 1, EPS power supply is AC220V, output is DC36V;2, communication adopts power carrier, two-wire output; 3. The current of any loop shall not exceed 6A; 4. No more than 50 lamps in any loop; 5. The total length of the power line of the loop is less than 200 m; 6. EPS is equipped with 36V battery to supply emergency power to lamps.
Key words:
Low voltage distribution box JD-PD-DC36
Distribution box 1. The input of distribution box is AC220V and the output is DC36V; 2. The current of any loop shall not exceed 6A; 3. The total length of loop power line is less than 200 m.
Key words:
The housing and urban-rural development departments of all provinces and autonomous regions, the housing and urban-rural development (management) committees of municipalities directly under the Central Government, the Beijing Municipal Planning and Natural Resources Commission, and the Housing and Urban-Rural Development Bureau of Xinjiang production and Construction Corps: examination and acceptance of fire protection design of construction projects (hereinafter referred to as fire inspection) is an important part of the reform of the examination and approval system of construction projects. In order to implement the work deployment of the 2023 National Housing and Urban-Rural Construction Work Conference, and to ensure that the fire inspection of all counties and cities above the county level will be included in the construction project approval management system (hereinafter referred to as the project approval system) by the end of the year, the relevant matters are hereby notified as follows:
Key words:
Following the general provisions of the Guangdong standard "Code for Acceptance of Fire Construction Quality of Building Engineering" (DBJ/T15-248-2022), the sub-projects involving fire protection are divided, and the fire detection requirements are improved, so that the fire quality acceptance content is incorporated into the existing construction engineering quality acceptance technology system, which provides a basis for all responsible parties to implement fire construction quality process control. Second, this regulation covers both housing construction projects and urban rail transit projects, and systematically combs, clarifies and refines the technical content, technical requirements, inspection quantity, and inspection methods of fire inspection implemented by the construction unit during the completion acceptance stage. Acceptance criteria.
Key words:
1. refers to different 1. Emergency evacuation indicator lamp: set to guide the trapped people to evacuate or launch fire fighting and rescue operations after the normal lighting power is cut off in the event of a fire. 2. Emergency evacuation lighting: It is a kind of lamp that can effectively illuminate and display the evacuation channel when the normal lighting power supply fails, or can continuously illuminate and work without interruption.
Key words:
Emergency light is a kind of lighting equipment specially designed to deal with emergencies
An emergency light is a lighting device specially designed to deal with emergencies. As part of emergency equipment, emergency lights have the characteristics of waterproof, fireproof, high brightness and eye-catching to ensure reliable lighting in emergency situations.
Key words:
Fire prevention is essential to protect people
Secondly, the emergency lights have fireproof characteristics. In the event of a disaster, such as a fire, short circuit, etc., fire protection is essential to protect the person. The fire protection design of emergency lights can effectively prevent lamps from causing greater disasters due to fires. Using fireproof materials and fireproof circuit design, emergency lights can work normally in emergency situations without causing a fire, ensuring people's lives and property.
Key words:
The eye-catching characteristics of emergency lights are also very important.
In addition, the eye-catching characteristics of the emergency light is also very important. In an emergency, people need to quickly identify the location of emergency lights in a short time. Emergency lights usually use bright colors, such as red, yellow, etc., and special flashing patterns,
Key words: